Medical Unit Converter
name: medical-unit-converter
by aipoch-ai · published 2026-04-01
$ claw add gh:aipoch-ai/aipoch-ai-medical-unit-converter---
name: medical-unit-converter
description: Convert medical laboratory values between units (mg/dL to mmol/L, etc.) with formula transparency and clinical reference ranges. Supports glucose, cholesterol, creatinine, and hemoglobin conversions.
license: MIT
skill-author: AIPOCH
---
# Medical Unit Converter
Convert laboratory values between clinical units with formula transparency and reference range context. Supports glucose, cholesterol, creatinine, and hemoglobin.
When to Use
Workflow
1. Confirm the user objective, required inputs, and non-negotiable constraints before doing detailed work.
2. Validate that the request matches the documented scope and stop early if the task would require unsupported assumptions.
3. Use the packaged script path or the documented reasoning path with only the inputs that are actually available.
4. Return a structured result that separates assumptions, deliverables, risks, and unresolved items.
5. If execution fails or inputs are incomplete, switch to the fallback path and state exactly what blocked full completion.
Supported Conversions
| Analyte | From | To | Factor | Reference Range (target unit) |
|---------|------|----|--------|-------------------------------|
| Glucose | mg/dL | mmol/L | 0.0555 | 3.9–5.6 mmol/L (fasting) |
| Glucose | mmol/L | mg/dL | 18.018 | 70–100 mg/dL (fasting) |
| Cholesterol | mg/dL | mmol/L | 0.02586 | < 5.2 mmol/L (desirable) |
| Cholesterol | mmol/L | mg/dL | 38.67 | < 200 mg/dL (desirable) |
| Creatinine | mg/dL | μmol/L | 88.4 | 62–115 μmol/L (male) |
| Creatinine | μmol/L | mg/dL | 0.01131 | 0.7–1.3 mg/dL (male) |
| Hemoglobin | g/dL | g/L | 10 | 130–175 g/L (male) |
| Hemoglobin | g/L | g/dL | 0.1 | 13–17.5 g/dL (male) |
Input Parameters
| Parameter | Type | Required | Description |
|-----------|------|----------|-------------|
| `--value`, `-v` | float | Yes | Numeric value to convert |
| `--from-unit` | str | Yes | Source unit (e.g., `mg_dl`, `mmol_l`, `umol_l`, `g_dl`, `g_l`) |
| `--to-unit` | str | Yes | Target unit |
| `--analyte`, `-a` | str | No | Analyte name for reference range lookup (e.g., `glucose`, `cholesterol`, `creatinine`, `hemoglobin`) |
Output Format
{
"converted_value": 5.55,
"formula": "100 × 0.0555",
"from_unit": "mg_dl",
"to_unit": "mmol_l",
"analyte": "glucose",
"reference_range": "3.9–5.6 mmol/L (fasting glucose)"
}Quick Check
python -m py_compile scripts/main.py
python scripts/main.py --value 100 --from-unit mg_dl --to-unit mmol_l --analyte glucoseImplementation Notes (for script developer)
The script must:
1. **Parse CLI args** — use argparse with `--value`, `--from-unit`, `--to-unit`, `--analyte`. Pass parsed args to `conv.convert()`. Do not hardcode demo values in `main()`.
2. **CONVERSIONS dict** — include all 8 conversion pairs above, each with `factor` and `reference_range` fields. Keys must be `(analyte, from_unit, to_unit)` tuples or equivalent nested structure.
3. **convert() method** — return a dict with `converted_value`, `formula`, `from_unit`, `to_unit`, `analyte`, `reference_range`.
4. **Unsupported pair** — if the unit pair is not in CONVERSIONS, print the supported conversions list and exit with code 1.
5. **Fallback Partial result** — when an unsupported unit pair is requested, always populate the `Partial result` field in the Fallback Template with: `"Manual formula not available for this unit pair"`.
Input Validation
This skill accepts: numeric laboratory values with a source unit and target unit for conversion between recognized clinical measurement systems.
If the request does not involve converting a specific numeric lab value between units — for example, asking to interpret clinical results, diagnose conditions, or convert non-laboratory quantities — do not proceed. Instead respond:
> "medical-unit-converter is designed to convert medical laboratory values between unit systems. Your request appears to be outside this scope. Please provide a numeric value with source and target units, or use a more appropriate tool for your task."
Error Handling
Fallback Template
When execution fails or inputs are incomplete, respond with this structure:
FALLBACK REPORT
───────────────────────────────────────
Objective : [restate the conversion goal]
Blocked by : [exact missing input or error]
Partial result : [manual formula if conversion factor is known; "Manual formula not available for this unit pair" if unsupported]
Next step : [minimum action needed to unblock]
───────────────────────────────────────Response Template
1. Objective
2. Inputs Received
3. Assumptions
4. Workflow
5. Deliverable
6. Risks and Limits
7. Next Checks
Prerequisites
No additional Python packages required beyond the standard library.
More tools from the same signal band
Order food/drinks (点餐) on an Android device paired as an OpenClaw node. Uses in-app menu and cart; add goods, view cart, submit order (demo, no real payment).
Sign plugins, rotate agent credentials without losing identity, and publicly attest to plugin behavior with verifiable claims and authenticated transfers.
The philosophical layer for AI agents. Maps behavior to Spinoza's 48 affects, calculates persistence scores, and generates geometric self-reports. Give your...